Ecoz Winter Cold Climate Low Cost Inverter Heat Pump/Intelligent Heating
US$2,745.00 - 3,358.00 | 1 Piece (MOQ) |
Guangzhou Yike New Energy Technology Co., Ltd.
Guangdong, China
Last Login Date:
Sep 15, 2024
Main Products:
Heat Pump Dryer, Heat Pump Water Heater, Central Air-Conditioning, Water Chiller
Product Description
Company Info
Basic Info.
Product Description
ECOZ inverter heat pump can be used for multiple purposes in one building, it can be directly connected to various terminals, including fan coils, heaters, floor heating, etc., with more flexible use. In addition to heating and cooling, ECOZ inverter heat pump can also be connected to the building's hot water system to achieve 24-hour hot water, summer cooling, and winter heating for home comfort integration.
Full DC inverter heat pump (cooling and heating) Technical Parameter | |||||
Model | KCL-05R/BP | KCL-06R/BP | KCL-07R/BP | ||
Rated Cooling | Rated Cooling Capacity | kW | 13.50 | 15.50 | 17.20 |
Cooling input power | kW | 4.69 | 5.34 | 5.81 | |
EER | W/W | 2.88 | 2.9 | 2.96 | |
Rated Heating | Rated Heating Capacity | kW | 18.00 | 22.00 | 24.00 |
Heating input power | kW | 4.48 | 5.01 | 5.87 | |
COP | W/W | 3.99 | 3.99 | 3.99 | |
Low-temperature heating | Rated Heating Capacity | kW | 10.5 | 12.1 | 13.8 |
Heating input power | kW | 4.65 | 5.31 | 6.05 | |
COP | W/W | 2.26 | 2.28 | 2.28 | |
Power Supply | V/Ph/Hz | 380/3/50 | |||
Maximum input power | kW | 5.5 | 6.6 | 6.6 | |
Maximum input current | A | 25.5 | 30 | 30 | |
Maximum water temperature | ºC | ||||
Rated hot water production | (L/H) | 355 | 440 | 515 | |
Matched floor heating area | (sqm) | 125 | 155 | 181 | |
Operating ambient temperature | C | '-30ºC-45ºC | |||
Refrigeration system | Refrigerant type | R410A | |||
Compressor | Quantity | 1 | |||
Type | Full DC inverter technology | ||||
Heat exchanger | / | High-efficiency hydrophilic aluminum foil fin heat exchanger | |||
Expansion valve | / | 600-level adjustment accuracy | |||
Fan System | Electric motor | Fan air volume | 3000m³/H×2 | ||
Quantity | 2 | ||||
Input power(W) | 2×90 | ||||
Water System | High-efficiency tank heat exchanger | ||||
Water flow switch | |||||
Power | 140W | ||||
pump lift/head | 8.3M | 7.8M | 6M | ||
Water flow | 2.32m3/H | 2.67m3/H | 2.96m3/H | ||
Inlet/outlet pipe | / | DN25 | |||
Dimension | Unit dimensions L/W/H | mm | 1030×440×1335 | ||
Noise | Outdoor unit | dB(A) | <=60 | <=58 | <=59 |
4. The use of high-quality spare parts effectively reduces the probability of frost formation and ensures the smooth operation of the unit in cold environments